HeRMeS-XC / Grading curve
Understanding the grading curve: D10, D30, D60, Cu and Cc
The grading curve summarises how the grains of a soil are distributed by size. Three diameters read from this curve, D10, D30 and D60, give two coefficients, Cu and Cc, which tell whether the soil is well spread or tight. Here is how to read and calculate them without mistakes.
What the curve shows
After sieving, the mass of soil passing through each sieve is known. The curve plots the grain diameter in millimetres on a logarithmic scale along the horizontal axis, and the cumulative percentage passing on the vertical axis, that is, the share of the total mass made of grains smaller than that diameter. The logarithmic scale is necessary: the grains of a single soil range from a few microns to several millimetres.
Reading D10, D30 and D60
The diameter Dx is the diameter such that x % of the soil mass is made of smaller grains. It is read from the curve at the ordinate x %.
- D10 : the diameter at 10 % passing: 10 % of the soil mass is finer than this diameter.
- D30 : the diameter at 30 % passing.
- D60 : the diameter at 60 % passing.
Measurements almost never fall exactly on 10, 30 or 60 %. You then interpolate between the two points of the curve that bracket the wanted value, working on the logarithm of the diameter and not on the diameter itself: a linear interpolation on the millimetres gives a wrong result.
The uniformity coefficient Cu
Cu = D60 / D10
Cu compares the coarse and the fine parts of the soil. It is always at least 1. The larger it is, the more spread the curve, that is, the more different grain sizes the soil contains. A Cu close to 1 indicates a uniform soil, whose grains are almost all the same size.
The curvature coefficient Cc
Cc = D30² / (D10 × D60)
Cc checks that the curve descends smoothly between D10 and D60. A Cc that is too small or too large indicates that an intermediate grain class is missing. Mind the square: it applies to D30 only.
Well-graded or poorly graded soil?
A soil is called well graded when its curve is spread out and smooth. The usual criteria, used by several classifications, are:
- for a gravel: Cu greater than 4 and Cc between 1 and 3;
- for a sand: Cu greater than 6 and Cc between 1 and 3.
The exact thresholds depend on the classification used in your report or specification. Apply the one the contract requires.
A worked example
Fictitious example, the one in the figure: D10 = 0.1 mm, D30 = 0.4 mm and D60 = 1.2 mm.
Cu = 1.2 / 0.1 = 12
Cc = 0.4² / (0.1 × 1.2) = 0.16 / 0.12 ≈ 1.33
With Cu = 12 and Cc between 1 and 3, this fictitious sand is well graded according to the criteria above.
When sieving is not enough
Sieving stops at grains of 80 micrometres. If more than 10 % of the soil passes this sieve, D10 is smaller than the last measured point: it is off the curve and Cu cannot be calculated. The test is then completed by a hydrometer (sedimentation) analysis, which studies particles smaller than 80 micrometres using a hydrometer, and the curve is continued with the sieving results.
Common mistakes
- Mixing up the passing (what goes through the sieve) and the retained (what it holds back): the curve plots the cumulative passing.
- Reading a diameter on a linear scale or interpolating on the millimetres.
- Forgetting the square of D30 in Cc.
- Calculating Cu with a D10 that is not on the curve, when the fines exceed 10 %.
- Mixing units: all diameters must be in the same unit.
Standards
Sieving is described by standard NF P 94-056 and hydrometer analysis by standard NF P 94-057. Both texts have been replaced by standard NF EN ISO 17892-4; many laboratories and specifications still cite the NF P references. Check the reference your contract requires, and consult the text of the standard for the test procedure.
In HeRMeS-XC
You enter your sieving weighings once. HeRMeS-XC calculates the passing percentages, plots the curve, gives the characteristic diameters and the coefficients Cu and Cc, then carries the result into the PDF report. You remain responsible for your measurements and for signing your report.
Read next: the Proctor test and the optimum water content. All the tests handled by HeRMeS-XC: the modules.